THE IMPACT OF THE UNIFIED POWER FLOW CONTROLLER ON MAXIMIZATION OF LOADABILITY OF ELECTRIC POWER GRID

Authors

  • SUNDAY ADETONA
  • RAIFU SALAWU
  • FRANK OKAFOR
  • JOSEPH ADEYEMI

DOI:

https://doi.org/10.29081/jesr.v26i4.231

Keywords:

loadability, fast voltage stability index, artificial bee colony algorithm, flexible alternating current transmission system, and unified power flow controller

Abstract

The building of additional transmission network to meet the demand of the ever-increasing load is expensive, and time consuming. An alternative to constructing new lines is the incorporation of the Flexible Alternating Current Transmission System (FACTS); in which a Unified Power Flow Controller (UPFC) is a member of the ménage, which can be modelled as a combination of Static Var Compensator and Thyristor Control Series Compensator. This study determines the optimal location of the UPFC by randomly adding loads to the existing transmission network until the Fast Voltage Stability Index of one of the lines is at a critical point. This is the vital line in which UPFC components are added. The sizing of the components of the UPFC is determined using Artificial Bee Colony algorithm. The IEEE 30-bus network is exploited as the test bed. The results obtained reveal that the optimal positioning and sizing of the UPFC for the purpose of maximizing loadability of the grid when load angles are assumed to be negligible are the same as when the load angles are considered. The loadability of the test bed when UPFC is not injected in the grid is 440.376 MW, whereas, it is 837.915 MW when the UPFC is optimally located and sized; and this represents 90.27 %. The sizes of the shunt and series components of the UPFC that assist in realizing this maximization are -0.2780 pu and 0.1000 pu respectively.

Downloads

Download data is not yet available.

Author Biographies

  • SUNDAY ADETONA

    Department of Electrical and Electronics Engineering, University of Lagos, Lagos, Nigeria

  • RAIFU SALAWU

    Department of Electronic and Computer Engineering, Bells University of Technology, Ota, Nigeria

  • FRANK OKAFOR

    Nigeria Nigerian Electricity Regulatory Commission, Abuja, Nigeria

  • JOSEPH ADEYEMI

    Department of Electrical and Electronics Engineering, University of Lagos, Lagos, Nigeria

Downloads

Published

2021-01-08

How to Cite

THE IMPACT OF THE UNIFIED POWER FLOW CONTROLLER ON MAXIMIZATION OF LOADABILITY OF ELECTRIC POWER GRID. (2021). Journal of Engineering Studies and Research, 26(4), 14-26. https://doi.org/10.29081/jesr.v26i4.231