NUMERICAL STUDY OF THE EFFECTS OF EVAPORATIVE COOLER SUPPLY AIR OUTLET HEIGHT ON THERMAL COMFORT

Authors

  • IBRAHIM USMAN HARUNA
  • IBRAHIM AHMAD RUFAI
  • BALARABE YAHAYA

DOI:

https://doi.org/10.29081/jesr.v28i2.002

Abstract

Thermal comfort in a space equipped with a direct evaporative cooler is a function of the height of the cooler's supply air outlet. This article attempts to numerically investigate the impact of hybrid downdraft evaporative cooler (HDEC) supply outlet height on occupant thermal comfort in an office building. DesignBuilder CFD parametric simulations was carried out by varying the height of the HDEC supply outlet from 0.1m to 2.4 m, step 0.1 m above ground level, using Predictive Mean Vote (PMV) as an objective function. The results show that the best PMV of -0.27 was obtained at 0.4m above the floor level.

Downloads

Download data is not yet available.

Author Biographies

  • IBRAHIM USMAN HARUNA

    Department of Mechanical Engineering, The Federal Polytechnic Mubi, Adamawa State, Nigeria

  • IBRAHIM AHMAD RUFAI

    Department of Mechanical Engineering, Bayero University Kano, Kano State, Nigeria

  • BALARABE YAHAYA

    Department of Mechanical Engineering, Bayero University Kano, Kano State, Nigeria

Downloads

Published

2022-09-01

How to Cite

NUMERICAL STUDY OF THE EFFECTS OF EVAPORATIVE COOLER SUPPLY AIR OUTLET HEIGHT ON THERMAL COMFORT. (2022). Journal of Engineering Studies and Research, 28(2), 17-24. https://doi.org/10.29081/jesr.v28i2.002